Grounding

The term "ground" refers to a conductive body, usually the earth. "Grounding" a tool or electrical system means intentionally creating a low-resistance path to the earth. When properly done, current from a short or from lightning follows this path, thus preventing the buildup of voltages that would otherwise result in electrical shock, injury and even death.

  • System or Service Ground: In this type of ground, a wire called "the neutral conductor" is grounded at the transformer, and again at the service entrance to the building. This is primarily designed to protect machines, tools, and insulation against damage.There are two kinds of grounds; both are required by the OSHA construction standard:
  • Equipment Ground: This is intended to offer enhanced protection to the workers themselves. If a malfunction causes the metal frame of a tool to become energized, the equipment ground provides another path for the current to flow through the tool to the ground.

There is one disadvantage to grounding: a break in the grounding system may occur without the user's knowledge. Using a ground-fault circuit interrupter (GFCI) is one way of overcoming grounding deficiencies.

Grounding Requirements

  • Ground all electrical systems.
  • The path to ground from circuits, equipment, and enclosures must be permanent and continuous.
  • Ground all supports and enclosures for conductors.
  • Ground all metal enclosures for service equipment.
  • Ground all exposed, non-current-carrying metal parts of fixed equipment.
  • Ground exposed, non-current-carrying metal parts of tools and equipment connected by cord and plug.
  • Ground the metal parts of the following non-electrical equipment:
  • Frames and tracks of electrically operated cranes.
  • Frames of non-electrically driven elevator cars to which electric conductors are attached.
  • Hand-operated metal shifting ropes or cables of electric elevators.
  • Metal partitions, grill work, and similar metal enclosures around equipment of over 1kV between conductors.

Methods of Grounding Equipment

  • Ground all fixed equipment with an equipment grounding conductor that is in the same raceway, cable, or cord, or that runs with or encloses the circuit conductors (except for DC circuits only).
  • Conductors used for grounding fixed or moveable equipment, including bonding conductors for assuring electrical continuity, must be able to safely carry any fault current that may be imposed on them.
  • Electrodes must be free from nonconductive coatings, such as paint or enamel, and if practicable, must be embedded below permanent moisture level.
  • Single electrodes which have a resistance to ground greater than 25 ohms must be augmented by one additional electrode installed no closer than 6 feet to the first electrode.

Source: U.S. Dept. of Labor Office of Safety & Health Administration

 
Fair Upfront Pricing  •  Give Us a Call Today  •  619-485-2772
 
 
Fair Upfront Pricing
Give us a Call today
619-485-2772
Schedule Service Online
 
 
Contact Information
 
4838 Ronson Court, Suite A  •  San Diego, CA 92111
Lic #: 931938 | 619-485-2772
4838 Ronson Court, Suite A  •  San Diego, CA 92111
Lic #: 931938 | 619-485-2772
 
Payment Options
 
 
Contact Information
 
4838 Ronson Court, Suite A  •  San Diego, CA 92111
Lic #: 931938 | 619-485-2772
4838 Ronson Court, Suite A  •  San Diego, CA 92111
Lic #: 931938 | 619-485-2772
 
Payment Options
 
Update your old electrical fuse box today in San Diego CA
Allow our plumber experts to repair your Plumbing in San Diego CA
Have your home electrical outlets, light fixtures, and wiring inspected by a certified electrician in Point Loma CA
Trust your home's plumbing to us for your next Plumbing in Point Loma CA
Trust Point Loma Electric and Plumbing to update the lighting in your home to new energy efficient LED lights in Santee CA
Join our maintenance plan for easy service for your Electrical units in San Diego CA
Have a certified electrician install your electrical ceiling fan in San Diego CA
Find out ways to save energy and money with Point Loma Electric and Plumbing whole house wiring repair service in San Diego CA
Trust our electrician to service your electrical repairs in Santee CA
Allow Point Loma Electric and Plumbing to repair your whole house wiring in Point Loma CA
Have a blown fuse, Call Point Loma Electric and Plumbing for a certified electrician in San Diego CA
See what makes Point Loma Electric and Plumbing your number one choice for Plumbing repair in Point Loma CA.
Did your Fuse blow, Call Point Loma Electric and Plumbing for a certified electrician in Point Loma CA
whole house wiring repair service in San Diego CA
Have a blown fuse, Call Point Loma Electric and Plumbing for a certified electrician in Santee CA
Plumbing repair service in Point Loma CA
Electrical repair service in San Diego CA
Plumber experts are ready to repair your Electrical in San Diego CA
Electrical repair service in Point Loma CA
Allow a plumber to come service your pipes in Santee CA
Home   |   Schedule   |   Get a Quote   |   Why Us   |   Testimonials   |   Join Our Team   |   About Our Company   |   Search
Home   |   Schedule Service
Get a Quote   |   Why Us   |   Testimonials
Join Our Team   |   About Our Company   |   Search